Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Clinical Endoscopy ; : 633-649, 2023.
Article in English | WPRIM | ID: wpr-1000090

ABSTRACT

Background/Aims@#Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability. @*Methods@#We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated. @*Results@#A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types. @*Conclusions@#MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.

2.
Clinical Endoscopy ; : 851-856, 2021.
Article in English | WPRIM | ID: wpr-914000

ABSTRACT

Background/Aims@#The recovery room used after endoscopy has limited capacity, and an efficient flow of the endoscopy unit is desired. We investigated the duration of hospital stay after endoscopy and the risk factors for prolonged hospital stay among outpatients. @*Methods@#We retrospectively studied consecutive patients who underwent esophagogastroduodenoscopy or colonoscopy at the Toyoshima Endoscopy Clinic. We collected data on age, sex, body weight, midazolam and pethidine dosage, respiratory depression during endoscopy, and duration of hospital stay after endoscopy (scope out to check out). Risk factors for prolonged hospital stay (>100 minutes) were identified using multiple logistic regression analysis. @*Results@#We enrolled 3,898 patients, including 3,517 (90.2%) patients tested under sedation and 381 (9.8%) patients tested without sedation. Overall, 442 (11.3%) patients had prolonged stay (>100 min). The mean time difference between sedation group and non-sedation group was 44.2 minutes for esophagogastroduodenoscopy and 39.1 minutes for colonoscopy. Age (odds ratio [OR], 1.025; 95% confidence interval [CI], 1.014−1.036), female sex (OR, 1.657; 95% CI, 1.220−2.249), and midazolam dose (OR, 1.019; 95% CI, 1.013−1.026) were independently associated with prolonged hospital stay after esophagogastroduodenoscopy, with similar results for colonoscopy. @*Conclusions@#Old age, female sex, and midazolam dose were independent risk factors for prolonged hospital stay after endoscopy.

3.
Gut and Liver ; : 481-488, 2017.
Article in English | WPRIM | ID: wpr-88949

ABSTRACT

BACKGROUND/AIMS: Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. METHODS: We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. RESULTS: The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. CONCLUSIONS: A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.


Subject(s)
Humans , Gastric Outlet Obstruction , Palliative Care , Pancreatitis , Retrospective Studies , Self Expandable Metallic Stents , Stents , Tertiary Care Centers
SELECTION OF CITATIONS
SEARCH DETAIL